The external battery can be placed on either side of the UPS unit. #Eaton powerware 9355 installation manual install#UPS 8 – 15 kV A, 40 0 V 50/60 Hz User ’ s Guide 1 023625 Revision C 12 Ext er nal bat t ery cabinet option It’ s recommended to install external battery cabinets next to the UPS unit. #Eaton powerware 9355 installation manual upgrade#Alternati vely the isolation transformer can be purc hased as a sepa- rate item to upgrade your existing system. The transformer is an integral part of the UPS unit. UPS 8 – 15 kV A, 40 0 V 50/60 Hz User ’ s Guide 1 023625 Revision C 1 1 T r ansfor mer option The galvanic isolation transformer can be ordered as factory installed. The maintenance Bypass Switch (MBS) when installed in the backside. UPS 8 – 15 kV A, 40 0 V 50/60 Hz User ’ s Guide 1 023625 Revision C 1 0 Figure 7. The same applies to the optional bat tery cabinets that should be installed next to the UPS cabinet. Cabinet installation The required distance for UPS units next to eac h other is ten millimetres. All cooling air enters at front and e xits at unit rea r. The equipment requires space to front and bac k to enable cooling airflow, service and maintenance. Planning bef or e installation The equipment must be installed in upright position. #Eaton powerware 9355 installation manual serial number#The serial number is important when making inquiri The type designation label includes ratings, a CE marking, a type code, a part number and a serial number. UPS 8 – 15 kV A, 40 0 V 50/60 Hz User ’ s Guide 1 023625 Revision C 7 Chec k the information on the type designation label of the equipment to verify that the unit is of the correct type. Do not either stac k the pallets because of hig Keep the UPS alw ays in upright position and do not drop the equipment. Mec hanical installation The UPS and accessories are delivered on a specifically designed pallet that is easy to move with a forklift or a pallet jac k. En vir onment The UPS must be installed according to the recommendations in this man F ailure t o r ecognise the electr ical hazards could pr ov e f atal. UPS 8 – 15 kV A, 40 0 V 50/60 Hz User ’ s Guide 1 023625 Revision C 5 W ar ning! The user is not per mit ted t o open of an y screws ex cluding connectivity plates and the MBS locking plat e. The properly installed enclosure is ear thed and IP20 rated ag ainst electri- cal shoc k and foreign objects. It contains components that car ry high currents and v oltages. Saf ety instr uctions The UPS operates with mains, bat tery or bypass power. UPS 8 – 15 kV A, 400 V 50/60 Hz User ’ s Guide 1 023625 r evision C Contents 1. Every care has been taken to ensure the accuracy of the information contained in this manual, but no liability can be accepted for any errors or omission. #Eaton powerware 9355 installation manual manual#©2007 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. User ’ s Guide UPS 8 – 15 kV A, 40 0 V 50/60 Hz output (3-phase input/output)
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |